Back to Product Guide - Process Instruments
4 1/2 DIGIT PROCESS RECEIVER
MODEL 2002A-P / 2002B-P / 3002-P
Made in the USA
Electromagnetic Compatibility
Year 2000 Compliant

Price List
Mechanical Reference
1/8 DIN (2A) Case
Mechanical Reference
Connections Diagram
STANDARD FEATURES
Span range from 0 to 19,999 counts
Zero range from -19,999 to +19,999 counts
120 dB CMR, 70 dB NMR
Bright, 0.56 in (14.2 mm) LED display
Display hold and test
115/230 V ac power
EMI/RFI filter for AC power
Screw-terminal barrier strip
Short (4.1 in, 104 mm deep) 1/8 DIN case

OPTIONS
Isolated 9-32 V dc or 26-56 V dc power
NEMA-4 splash-proof lens cover

Model 2002A-P is a low-cost, high-resolution 4 1/2 digit panel meter for process signals that require zero and span adjustment for readout in engineering units. The resolution is 1 part in ±19,999 counts, or 0.005% of full scale. Acccuracy is up to 99.98% of reading.

The 2002A-P can be used in ratiometric pot-follower applications to determine liquid level or valve setting from the position of a potentiometer wiper. The required external reference voltage can be derived from the meter's own 4.7 V dc supply. The 2002A-P is housed in a short 1/8 DIN case that requires less than 4.1 in (104 mm) behind the panel. A screw-terminal barrier strip is standard for signal and power. Options include isolated 9-32 V dc and 26-56 V dc power. A splash-proof lens cover which meets NEMA-4 requirements allows the 2002A to be used in harsh industrial environments.

SPECIFICATIONS

ANALOG INPUT
Signal Range
4-20 mA
1-5 V
0-10 V
Resolution
0.8 µA
0.2 mV
0.5 mV
Input resistance
130 ohm
1 Mohm
1 Mohm
Bias current
50 pA
10 pA
5 pA
Maximum input
55 mA
250 V
250 V

Span range:
0 to 19,999 counts
Zero range: ­19,999 to +19,999 counts

REFERENCE
Internal (standard): 1.0 V ±5%, 12 kohm source resistance
External (ratiometric): 0.5 to 2.0 V, 680 kohm input resistance


ACCURACY AT 25°C
REFERENCE
INTERNAL
EXTERNAL
Maximum error
±0.01% of span
±0.01% of span
±2 counts
±2 counts
Zero tempco
±0.5 counts/°C
±1 count/°C
Span tempco
±0.01% of span/°C
±0.005% of span/°C
Full-scale step response: 1.0 s
Warmup to rated accuracy: 10 min

NOISE REJECTION
NMR, SIG HI to SIG LO:
70 dB, 50/60 Hz
CMR, SIG GND to PWR GND: 120 dB, DC to 60 Hz
CMV, SIG GND to PWR GND: 1500 Vp per HV test, 354 Vp per IEC spacing

ANALOG-TO-DIGITAL CONVERSION
Technique:
Dual-slope, average value
Signal integration period: 100 ms
Read rate: 2.5/s

DISPLAY
Type:
7-segment, red LED
Height: 0.56 in (14.2 mm)
Symbols: ­1.8.8.8.8
Decimal points: Four positions, programmable by jumpers behind lens or at connector, 10 mA sink to DIG GND
Overrange indication: Four least-significant digits flash

DIGITAL INPUTS
Siganls:
Display hold, blanking, display test, decimal point select
Level: TTL or 5 V CMOS compatible

POWER
AC voltages:
115 or 230 V ac, ±15%
AC frequency: 49 to 440 Hz
DC voltages: 9-32 V dc, isolated to 300 Vp; 26-56 V dc, isolated to 300 Vp
Power consumption: 4.0 W
Output voltages: +4.7 V dc and ­4.7 V dc ±5%, 10 mA max

ENVIRONMENTAL
Operating temperature:
0 to 60°C
Storage temperature: ­40 to +85°C
Relative humidity: 95% at 40°C (non-condensing)

MECHANICAL
Dimensions:
Newport DIN2A (short 1/8 DIN) case (see Mechanical section for drawings)
Weight: 15 oz (425 g)
Case material: 94V-0 UL-rated polycarbonate
Connectors - Power & signal: D4 screw-terminal barrier strip (std)
Display control: D1 36-pin PCB edge connector (opt)




Fast Quotes on Products

HOME / PRODUCT GUIDE / TECHNICAL REFERENCE